Compact systems for cooling and aeration of wort . The compact unit includes the plate heat exchanger for cooling of hot wort to the beer fermentation temperature. Wort is saturated too by pure air or oxygen to easy start of the yeast activity during the beer fermentation.

Wort flow-through thermometer
FTTM-B38 Flow-through thermometer 3/8 inches
FTTM-B38 Flow-through thermometer 3/8 inch

FTTM-B38 is an in-line flow-through thermometer that fits to water and wort temperature indication during the wort cooling process. This thermometer is equipped with two hose connectors (for hoses with inner diameter 3/8inch / 9.5mm).

not rated  49 excluding tax Add to Cart
WCASB-150 Compact cooler and aerator of wort 150 liters per hour
WCASB-150 Compact cooler and aerator of wort 150 liters per hour
WCASB-150 Compact cooler and aerator of wort 150 liters per hour

Compact cooler and aeration system for wort with performance 150 liters of wort per hour. The block system for precisse cooling and aeration of hot wort. This is a necessary equipment for preparation of wort after the hot wort brewing process and before start of the beer fermentation process. Two-stage tabular heat exchanger intended for cooling of the wort from 98 ° C to 7 ° C using 15 ° C and 1 ° C water before starting of beer fermentation process. The plate heat exchanger and the aeration candle are attached to a stainless steel panel which is equipped with temperature sensors and digital displays.

not rated  3802 4206 excluding tax Add to Cart
WCASB-300 Compact cooler and aerator of wort 300 liters per hour
WCASB-300 Compact cooler and aerator of wort 300 liters per hour
WCASB-300 Compact cooler and aerator of wort 300 liters per hour

Compact cooler and aeration system for wort with performance 300 liters of wort per hour. The block system for precisse cooling and aeration of hot wort. This is a necessary equipment for preparation of wort after the hot wort brewing process and before start of the beer fermentation process. Two-stage tabular heat exchanger intended for cooling of the wort from 98 ° C to 7 ° C using 15 ° C and 1 ° C water before starting of beer fermentation process. The plate heat exchanger and the aeration candle are attached to a stainless steel panel which is equipped with temperature sensors and digital displays.

not rated  3922 4326 excluding tax Add to Cart
WCASB-500 Compact cooler and aerator of wort 500 liters per hour
WCASB-500 Compact cooler and aerator of wort 500 liters per hour
WCASB-500 Compact cooler and aerator of wort 500 liters per hour

Compact cooler and aeration system for wort with performance 500 liters of wort per hour. The block system for precisse cooling and aeration of hot wort. This is a necessary equipment for preparation of wort after the hot wort brewing process and before start of the beer fermentation process. Two-stage tabular heat exchanger intended for cooling of the wort from 98 ° C to 7 ° C using 15 ° C and 1 ° C water before starting of beer fermentation process. The plate heat exchanger and the aeration candle are attached to a stainless steel panel which is equipped with temperature sensors and digital displays.

not rated  4042 4446 excluding tax Add to Cart
WCASB-800 Compact cooler and aerator of wort 800 liters per hour
WCASB-800 Compact cooler and aerator of wort 800 liters per hour
WCASB-800 Compact cooler and aerator of wort 800 liters per hour

Compact cooler and aeration system for wort with performance 800 liters of wort per hour. The block system for precisse cooling and aeration of hot wort. This is a necessary equipment for preparation of wort after the hot wort brewing process and before start of the beer fermentation process. Two-stage tabular heat exchanger intended for cooling of the wort from 98 ° C to 7 ° C using 15 ° C and 1 ° C water before starting of beer fermentation process. The plate heat exchanger and the aeration candle are attached to a stainless steel panel which is equipped with temperature sensors and digital displays.

not rated  4385 4789 excluding tax Add to Cart
WCASB-1001 Compact cooler and aerator of wort 1000 liters per hour
WCASB-1001 Compact cooler and aerator of wort 1000 liters per hour
WCASB-1001 Compact cooler and aerator of wort 1000 liters per hour

The block system for precisse cooling and aeration of hot wort. This is a necessary equipment for preparation of wort after the hot wort brewing process and before start of the beer fermentation process. One-stage tabular heat exchanger intended for cooling of the wort from 98 ° C to 7 ° C using  1 ° C water before starting of the beer fermentation process. The plate heat exchanger and the aeration candle are attached to a stainless steel panel which is equipped with temperature sensors and digital displays. Temperature sensors allow precise adjustment of the flow of media. Control elements are used for switching functions of the wort cooling system for manual or automatic operation.

not rated  4490 excluding tax Add to Cart
WCASB-1000 Compact cooler and aerator of wort 1000 liters per hour
WCASB-1000 Compact cooler and aerator of wort 1000 liters per hour
WCASB-1000 Compact cooler and aerator of wort 1000 liters per hour

Compact cooler and aeration system for wort with performance 1000 liters of wort per hour. The block system for precisse cooling and aeration of hot wort. This is a necessary equipment for preparation of wort after the hot wort brewing process and before start of the beer fermentation process. Two-stage tabular heat exchanger intended for cooling of the wort from 98 ° C to 7 ° C using 15 ° C and 1 ° C water before starting of beer fermentation process. The plate heat exchanger and the aeration candle are attached to a stainless steel panel which is equipped with temperature sensors and digital displays.

not rated  4728 5131 excluding tax Add to Cart
WCASB-1500 Compact cooler and aerator of wort 1500 liters per hour
WCASB-1500 Compact cooler and aerator of wort 1500 liters per hour
WCASB-1500 Compact cooler and aerator of wort 1500 liters per hour

Compact cooler and aeration system for wort with performance 1500 liters of wort per hour. The block system for precisse cooling and aeration of hot wort. This is a necessary equipment for preparation of wort after the hot wort brewing process and before start of the beer fermentation process. Two-stage tabular heat exchanger intended for cooling of the wort from 98 ° C to 7 ° C using 15 ° C and 1 ° C water before starting of beer fermentation process. The plate heat exchanger and the aeration candle are attached to a stainless steel panel which is equipped with temperature sensors and digital displays.

not rated  6644 7048 excluding tax Add to Cart
WCASB-2000 Compact cooler and aerator of wort 2000 liters per hour
WCASB-2000 Compact cooler and aerator of wort 2000 liters per hour
WCASB-2000 Compact cooler and aerator of wort 2000 liters per hour

Compact cooler and aeration system for wort with performance 2000 liters of wort per hour. The block system for precisse cooling and aeration of hot wort. This is a necessary equipment for preparation of wort after the hot wort brewing process and before start of the beer fermentation process. Two-stage tabular heat exchanger intended for cooling of the wort from 98 ° C to 7 ° C using 15 ° C and 1 ° C water before starting of beer fermentation process. The plate heat exchanger and the aeration candle are attached to a stainless steel panel which is equipped with temperature sensors and digital displays.

not rated  7658 8062 excluding tax Add to Cart
WCASB-3000 Compact cooler and aerator of wort 3000 liters per hour
WCASB-3000 Compact cooler and aerator of wort 3000 liters per hour
WCASB-3000 Compact cooler and aerator of wort 3000 liters per hour

Compact cooler and aeration system for wort with performance 3000 liters of wort per hour. The block system for precisse cooling and aeration of hot wort. This is a necessary equipment for preparation of wort after the hot wort brewing process and before start of the beer fermentation process. Two-stage tabular heat exchanger intended for cooling of the wort from 98 ° C to 7 ° C using 15 ° C and 1 ° C water before starting of beer fermentation process. The plate heat exchanger and the aeration candle are attached to a stainless steel panel which is equipped with temperature sensors and digital displays.

not rated  9643 10047 excluding tax Add to Cart
WCASB-3002 Two-stage block wort cooler-aerator 2×3000 liters per hour
WCASB-3002 Two-stage block wort cooler-aerator 2×3000 liters per hour
WCASB-3002 Two-stage block wort cooler-aerator 2×3000 liters per hour

The block system for precisse cooling and aeration of hot wort. This is a necessary equipment for preparation of wort after the hot wort brewing process and before start of the beer fermentation process. The cooling system includes two plate heat exchangers. 1st heat exchanger is designed for cooling  of wort from 98°C to appoximaly 30°C using cold drink water  (12°-18°C) and purchasing hot water with temperature 80°C. 2nd heat exchanger is designed for cooling wort from 30°C to approximaly 7-12°C (for bottom fermented beer types) or 15-24°C (for top fermented beer types) using cold glycol (-4°C). The plate heat exchanger and the aeration candle are attached to a stainless steel panel which is equipped with temperature sensors and digital displays.

not rated  18800 19204 excluding tax Add to Cart
WCASB-4000 Compact cooler and aerator of wort 4000 liters per hour
WCASB-4000 Compact cooler and aerator of wort 4000 liters per hour
WCASB-4000 Compact cooler and aerator of wort 4000 liters per hour

Compact cooler and aeration system for wort with performance 4000 liters of wort per hour. The block system for precisse cooling and aeration of hot wort. This is a necessary equipment for preparation of wort after the hot wort brewing process and before start of the beer fermentation process. Two-stage tabular heat exchanger intended for cooling of the wort from 98 ° C to 7 ° C using 15 ° C and 1 ° C water before starting of beer fermentation process. The plate heat exchanger and the aeration candle are attached to a stainless steel panel which is equipped with temperature sensors and digital displays.

not rated  12498 13579 excluding tax Add to Cart
WCASB-5000 Compact cooler and aerator of wort 5000 liters per hour
WCASB-5000 Compact cooler and aerator of wort 5000 liters per hour
WCASB-5000 Compact cooler and aerator of wort 5000 liters per hour

Compact cooler and aeration system for wort with performance 5000 liters of wort per hour. The block system for precisse cooling and aeration of hot wort. This is a necessary equipment for preparation of wort after the hot wort brewing process and before start of the beer fermentation process. Two-stage tabular heat exchanger intended for cooling of the wort from 98 ° C to 7 ° C using 15 ° C and 1 ° C water before starting of beer fermentation process. The plate heat exchanger and the aeration candle are attached to a stainless steel panel which is equipped with temperature sensors and digital displays.

not rated  13579 13983 excluding tax Add to Cart
WCASB-6000 Compact cooler and aerator of wort 6000 liters per hour
WCASB-6000 Compact cooler and aerator of wort 6000 liters per hour
WCASB-6000 Compact cooler and aerator of wort 6000 liters per hour

Compact cooler and aeration system for wort with performance 6000 liters of wort per hour. The block system for precisse cooling and aeration of hot wort. This is a necessary equipment for preparation of wort after the hot wort brewing process and before start of the beer fermentation process. Two-stage tabular heat exchanger intended for cooling of the wort from 98 ° C to 7 ° C using 15 ° C and 1 ° C water before starting of beer fermentation process. The plate heat exchanger and the aeration candle are attached to a stainless steel panel which is equipped with temperature sensors and digital displays.

not rated  15600 16004 excluding tax Add to Cart
PHE-SWP250 Plate heat exchanger B10x80
PHE-SWP250 Plate heat exchanger B10x80
PHE-SWP250 Plate heat exchanger B10x80

PHE-SWP250 is the brazed (not be dismantled) plate heat exchanger with architecture B10x80. This equipment is used for the cooling of beer wort with maximal capacity 250 liters of beer wort per one hour, cooling down from 90°C to 25°C (if cold water 12°C is used as coolant) or from 25°C to 6°C (if glycol -4°C is used)  . Two pieces of this PHE (double PHE system) are able to cool wort from 90°C to 6°C .

not rated  724 excluding tax Add to Cart
PHE-SWP500 Plate heat exchanger B28x86
PHE-SWP500 Plate heat exchanger B28x86
PHE-SWP500 Plate heat exchanger B28x86

PHE-SWP500 is the brazed (not be dismantled) plate heat exchanger with architecture B28x86. This equipment is used for the cooling of beer wort with maximal capacity 500 liters of beer wort per one hour, cooling down from 90°C to 25°C (if cold water 12°C is used as coolant) or from 25°C to 6°C (if glycol -4°C is used)  . Two pieces of this PHE (double PHE system) are able to cool wort from 90°C to 6°C .

not rated  826 excluding tax Add to Cart
PHE-SWP1000 Plate heat exchanger B120Tx80
PHE-SWP1000 Plate heat exchanger B120Tx80
PHE-SWP1000 Plate heat exchanger B120Tx80

PHE-SWP1000 is the brazed (not be dismantled) plate heat exchanger with architecture B120Tx80. This equipment is used for the cooling of beer wort with maximal capacity 1000 liters of beer wort per one hour, cooling down from 90°C to 25°C (if cold water 12°C is used as coolant) or from 25°C to 6°C (if glycol -4°C is used)  . Two pieces of this PHE (double PHE system) are able to cool wort from 90°C to 6°C .

not rated  1642 excluding tax Add to Cart
PHE-GLP-500L9025 Plate heat exchanger 500 lt/hour
PHE-GLP-500L9025 Plate heat exchanger 500 lt/hour
PHE-GLP-500L9025 Plate heat exchanger 500 lt/hour

The PHE-GLP-500L9025 is a dismountable plate heat exchanger. This equipment is used for the cooling of beer wort with capacity : 500 liters of beer wort per one hour, cooling down from 90°C to 25°C or from 25°C to 6°C. Two pieces of this PHE (double PHE system) are able to cool wort from 90°C to 6°C.

not rated  1228 excluding tax Add to Cart
PHE-GLP-1000L9025 Plate heat exchanger 1000 lt/hour
PHE-GLP-1000L9025 Plate heat exchanger 1000 lt/hour
PHE-GLP-1000L9025 Plate heat exchanger 1000 lt/hour

The PHE-GLP-1000L9025 is a dismountable plate heat exchanger. This equipment is used for the cooling of beer wort with capacity : 1000 liters of beer wort per one hour, cooling down from 90°C to 25°C or from 25°C to 6°C. Two pieces of this PHE (double PHE system) are able to cool wort from 90°C to 6°C.

not rated  1465 excluding tax Add to Cart
PHE-KST-500L9025 Plate heat exchanger 500 lt/hour
PHE-KST-500L9025 Plate heat exchanger 500 lt/hour
PHE-KST-500L9025 Plate heat exchanger 500 lt/hour

The PHE-KST-500L9025 is a plate heat exchanger, completely made of stainless steel, top industry unit. Food industry fittings according to DIN 11851. This equipment is used for the cooling of beer wort with capacity : 500 liters of beer wort per one hour, cooling down from 90°C to 25°C or from 25°C to 6°C. Two pieces of this PHE (double PHE system) are able to cool wort from 90°C to 6°C.

not rated  3381 excluding tax Add to Cart