Products » CSE : Cooling systems, equipment » CCW : Compact wort coolers » WCASB-150 : Compact cooler and aerator of wort 1000 liters per hour with LED temperature indicators
NOW DISCOUNT!

WCASB-150 : Compact cooler and aerator of wort 1000 liters per hour with LED temperature indicators

 4228 4661 excluding tax

Compact cooler and aeration system for wort 150 liters of wort per hour which is attached to a stainless steel panel with LED temperature indicators.
The monoblock system for precisse cooling and aeration of hot wort. This is a necessary equipment for preparation of wort after the hot wort brewing process and before start of the beer fermentation process.
Single-stage or double-stage tabular heat exchanger intended for cooling of the wort from 90°C to 25-7°C using water at temperature 15°C and 1°C before starting of beer fermentation process. The plate heat exchanger and the aeration candle are attached to a stainless steel panel which is equipped with temperature sensors and digital displays.

Clear selection

Description

Print Friendly, PDF & Email

Compact cooler and aeration system for wort 150 liters of wort per hour which is attached to a stainless steel panel with LED temperature indicators.

The monoblock system for precisse cooling and aeration of hot wort. This is a necessary equipment for preparation of wort after the hot wort brewing process and before start of the beer fermentation process.

Single-stage or double-stage tabular heat exchanger intended for cooling of the wort from 90°C to 25-7°C using water at temperature 15°C and 1°C before starting of beer fermentation process. The plate heat exchanger and the aeration candle are attached to a stainless steel panel which is equipped with temperature sensors and digital displays.

Temperature sensors allow precise adjustment of the flow of media. Control elements are used for switching functions of the wort cooling system for manual or automatic operation.

 


We offer the compact wort cooler-aerator in two versions :

The single-stage plate heat exchanger :

This version includes one circuit for water, one circuit for wort, one inlet for sterile air or oxygen, four thermo sensors and four LED temperature indicators :
– Cold water temperature at the water inlet (usually -1-15°C)
– Hot water temperature at the water outlet (usually 80-85°C)
– Temperature of the wort at the wort intlet (usually 90°C)
– Temperature of the wort at the wort outlet (usually 7-25°C)
Manometer shows pressure of sterile air on inlet to the aeration candle.

 

The double-stage plate heat exchanger :

This version includes two circuits for water, one circuit for wort, one inlet for sterile air or oxygen, six thermo sensors and six LED temperature indicators :
– Cold water temperature at the inlet of the 1st stage (usually 15°C)
– Hot water temperature at the outlet of the 1st stage (usually 80-85°C)
– Ice water temperature at the inlet of the 2nd stage (usually 1°C)
– Cold water temperature at the outlet of the 2nd stage (usually 15°C)
– Temperature of the wort at the intlet (usually 90°C)
– Temperature of the wort at the outlet (usually 7-25°C)
Manometer shows pressure of sterile air on inlet to the aeration candle.

 

Technical specification and equipment
Single-stage wort cooler Double-stage wort cooler
Number of chambers (plates) – totally 20 20
Number of chambers (plates) – 1st stage 12
Number of chambers (plates) – 2nd stage 8
Temperature of hot wort (the wort inlet) 90°C 90°C
Temperature of cold wort (the wort outlet) 25°C (water at 15°C) /  7°C (water at 1°C) 25°C (1st water at 15°C) /  7°C (2nd water at 1°C)
Temperature of cold water (1st stage / water inlet) 15°C (for top fermenting beer) / 1°C (for bottom fermenting beer) 25°C
Temperature of hot water (1st stage / water outlet) 80-85°C 80-85°C
Temperature of ice water (2nd stage / water inlet) 1°C
Temperature of warm water (2nd stage / water outlet) 3-5°C
Aeration candle DN10 with the solenoid valve Yes Yes
Manometer (sterile pressure air or medical oxygen) 0 – 4bar 0 – 4bar
Digital thermometer DIXELL XT11S 4 pcs 6 pcs
Temperature sensor 4 pcs 6 pcs
Cold water flow control valve DN 25 ( 1″ ) DN 25 ( 1″ )
Wort inlet (connection type) DN 25 (DIN 11851 or DIN 32676) DN 25 (DIN 11851 or DIN 32676)
Wort outlet (connection type) DN 25 (DIN 11851 or DIN 32676) DN 25 (DIN 11851 or DIN 32676)
1st stage : cold water inlet (connection type) BSP 1″ / external thread BSP 1″ / external thread
1st stage : hot water outlet (connection type) BSP 1″ / external thread BSP 1″ / external thread
2nd stage : ice water inlet (connection type) BSP 1″ / external thread
2nd stage : ice water outlet (connection type) BSP 1″ / external thread
Pressure air input (connection type) BSP 1/2″ / external thread BSP 1/2″ / external thread
Terminal for remote control yes yes
Contactor for start the pump of ice water yes yes
Electric power supply EU standard plug : 1-phase 230V/ 50hz /16A EU standard plug : 1-phase 230V/ 50hz /16A
Dimensions (A x B x C) 900 x 600 x 420 mm 1100 x 800 x 420 mm
Weight 90 kg 110 kg

 

wort-cooler-aerator-002-800x800

 

 

 

 

Additional information

Weight 95 kg
Dimensions 320 × 280 × 1200 mm
Cooling

Single-stage, Double-stage

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.