Description
TTMACS-42 Automatic control of cold process – media and 1-42 tanks
The automatic control system TTMACS-42 allows automatic monitoring and controlling of the most important parts of beer fermentation and maturation process (from 1 to 42 tanks max with one-zone control) and operations with media.
TTMACS-42 allows measuring and control of :
- HWT – heat water tank
- ITWT – ice treated water tank
- ICWT – ice cooling water tank
- WCA – wort cooler and aerator
- LCS – glycol medium cooler
- Beer tanks (from 1 to 42 pcs total max) :
The automatic control system TTMACS-42 consists of :
- Automatic control of HWT (heat water tank)
- minimal-maximal water level control
- emergency alarm
- automatic water filling
- automatic water heating
- automatic water temperature homogenization by pump
- signal communication with the brewhouse (you can not run the brewhouse until the requested temperature in the tank)
- vizualization of all processes
- Automatic control of ITWT (ice treated water tank)
- minimal-maximal water level control
- frost water protection
- emergency alarm
- automatic water filling
- automatic water cooling
- automatic water temperature homogenization by pump
- signal communication with the brewhouse (you can not run the brewhouse until the requested temperature in the tank)
- vizualization of all processes
- Automatic control of ICWT (ice cooling water tank)
- minimal-maximal water level control
- all temperatures control
- frost water protection
- emergency alarm
- automatic water filling
- automatic water cooling
- signal communication with the CCT´s – cooling od demand
- vizualization of all processes
- Automatic control of fermentation and maturation process (C-C tanks or opened fermentation vats)
- all temperatures control for fermentation and maturation process
- setting of temperature timeplan for each tank (max. 90 days)
- recording of temperature history for each tank (max. 90 days)
- export data to websites
- remote control and visualization
- display of set and real temperatures in each tank
- frost water and yeast protection
- output on GSM gateway or ALARM
- signal communication with the IWT – cooling od demand
- vizualization of all processes on local LCD panel and remote computers
Manual operations
- Sanitisation of tanks
- Connection of CIP to tanks
- Connection of tanks to heat exchanger
- Add of yeast into tanks
- Pumping of beer between vessels
- Filtering and cleaning of filter
- Racking
The control programme operates in czech, russian and english language.